Mitsubishi Electric MELSEC iQ-R-R00CPU User Manual page 930

Melsec iq-r series cpu module application user's manual
Table of Contents

Advertisement

D2 is determined as follows.
Item
Global device (other than the refresh data
register (RD))
Local device
*3
Global label
*3
Local label
*2 The size of the devices/labels to be transferred (tracked) can be checked by clicking the [Size Calculation] button in "Detailed Setting" of
"Device/Label Detailed Setting". ( Page 462 Detailed setting)
*3 Even though global labels/local labels are deleted by the online change, the size of the tracking data of the global labels/local labels are
the same as the one before the online change. The size is updated when the program and global label setting file to which all data is
rebuilt (reassigned) are written to the programmable controller and the operating status of the CPU module is switched from STOP to
RUN.
*4 This indicates the number of programs where local devices are set to use in the "Setting of Device/File Use Or Not" window of the
program setting of the CPU parameter.
D4 is determined as follows.
Item
System data
Signal flow memory (standard/safety)
Refresh data register (RD)
*5 When calculating D7, use this value for "System data (safety)".
*6 Since the maximum number of mountable CC-Link IE Field Network module is 8, the maximum number of connections that can be set in
the safety communication setting is 960 (120 connections  8 modules).
D5 is determined as follows.
Item
Global device (standard) (other than the refresh
data register (RD))
Global device (safety)
Local device (standard/safety)
*8
Global label (standard)
*8
Global label (safety)
*8
Local label (standard)
*8
Local label (safety)
Standard/safety shared label
*7 The size of the devices/labels to be transferred (tracked) can be checked by clicking the [Size Calculation] button in "Detailed Setting" of
"Device/Label Detailed Setting". ( Page 462 Detailed setting)
*8 Even though global labels/local labels are deleted by the online change, the size of the tracking data of the global labels/local labels are
the same as the one before the online change. The size is updated when the program and global label setting file to which all data is
rebuilt (reassigned) are written to the programmable controller and the operating status of the CPU module is switched from STOP to
RUN.
*9 This indicates the number of programs where local devices are set to use in the "Setting of Device/File Use Or Not" window of the
program setting of the CPU parameter.
APPX
928
Appendix 9 Processing Time
*2
Size
Follows the tracking transfer settings. ( Page 460 Tracking transfer setting)
Total size of local devices of the device/label memory area detailed setting  the number of programs on the
*4
program setting
Follows the global label settings.
Follow the local label settings.
Size
■Fixed data
7602
■PID control instruction information
782 (0 (when not used))
■Data that varies depending on the tracking device/label setting
16  (No. of tracking settings of T, ST, C, and LC) + 8  (No. of global device tracking settings of other
devices)
■Variable depending on safety communication status
136 + (29  (Number of connections set in the safety communication setting of all the modules
(Total number of steps of control system execution programs, or total number of steps of rising/falling
instruction in an FB)/16
(The digit after the decimal point is round up.)
Follows the tracking transfer settings. ( Page 628 Tracking transfer setting)
*7
Size
Follows the tracking transfer settings. ( Page 628 Tracking transfer setting)
Follows the safety device/label area in the device/label memory settings.
Total size of local devices of the device/label memory area detailed setting  the number of programs on the
*9
program setting
Follows the global label settings.
Follows the safety global label settings.
Follows the local label settings of each standard program.
Follows the local label settings of each safety program.
Follows the standard/safety shared label setting file.
*5
*6
)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents