Mitsubishi Electric MELSEC iQ-R-R00CPU User Manual page 707

Melsec iq-r series cpu module application user's manual
Table of Contents

Advertisement

Error
Error name
Error details and cause
code
112EH
Connection
• A connection could not be
establishment
established in the open
failed
processing.
1133H
Socket
• The response send failed during
communications
socket communications.
response send
error
1134H
TCP connection
• A TCP ULP timeout error has
timeout
occurred in the TCP/IP
communication. (The external
device does not send an ACK
response.)
1152H
IP address error
• The IP address is not set correctly.
1155H
Connection
• The specified connection was
number
already closed in TCP/IP
acquisition error
communications.
• Open processing is not
performed.
1157H
Receive buffer
• The specified connection was
securement
already closed in UDP/IP
error
communications.
• Open processing is not
performed.
Stop/
Action
continue
Continue
• Check the operation of the external
device.
• Check if the open processing has been
performed in the external device.
• Check and correct the port number of
the module, IP address/port number of
the external device, and opening
method.
• When the firewall is set in the external
device, check if the access is
permitted.
• Check if the Ethernet cable is
disconnected.
Continue
• Check the operation of the external
device or switching hub.
• Since there may be congestion of
packets on the line, send data after a
certain period of time.
• Check if the Ethernet communication
load is high because of the Ethernet
functions being executed. Use the
Ethernet functions so that the
communication load is reduced.
• Check if the connection cable is
disconnected.
• Check that there is no connection
failure with the switching hub.
Continue
• Check the operation of the external
device.
• Check and correct the TCP ULP
timeout value.
• Since there may be congestion of
packets on the line, send data after a
certain period of time.
• Check if the Ethernet communication
load is high because of the Ethernet
functions being executed. Use the
Ethernet functions so that the
communication load is reduced.
• Check if the connection cable is
disconnected.
Continue
• Correct the IP addresses.
Continue
• Perform the open processing for the
specified connection.
• Check if the open processing has been
performed in the external device.
Continue
• Perform the open processing for the
specified connection.
• Check if the open processing has been
performed in the external device.
Detailed
Diagnostic
information
timing
Always
Always
Always
Parameter
Always
information
Always
Always
APPX
705
Appendix 1 Error Codes
A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents