Safety Information - Mitsubishi Electric MELSEC iQ-R-R00CPU User Manual

Melsec iq-r series cpu module application user's manual
Table of Contents

Advertisement

Safety information

The following is a list of special relay areas relating to safety information.
No.
Name
SM1840
Allowed time over flag
for continuous RUN in
TEST MODE
SM1888
Safety cycle processing
time execution cycle
error flag
SM1904
CC-Link IE Field
Network safety
communication setting
(1st module)
SM1905
CC-Link IE Field
Network safety
communication setting
(2nd module)
SM1906
CC-Link IE Field
Network safety
communication setting
(3rd module)
SM1907
CC-Link IE Field
Network safety
communication setting
(4th module)
SM1908
CC-Link IE Field
Network safety
communication setting
(5th module)
SM1909
CC-Link IE Field
Network safety
communication setting
(6th module)
SM1910
CC-Link IE Field
Network safety
communication setting
(7th module)
SM1911
CC-Link IE Field
Network safety
communication setting
(8th module)
APPX
832
Appendix 4 List of Special Relay Areas
Data stored
Details
Off: Within the specified
This relay turns on when the continuous RUN
time
time in TEST MODE has exceeded the
On: Specified time
allowed time set in the CPU parameter, and
exceeded
turns off in the following cases.
Off: No error (normal)
On: Error
Off: Not set
On: Set
Off: Not set
On: Set
Off: Not set
On: Set
Off: Not set
On: Set
Off: Not set
On: Set
Off: Not set
On: Set
Off: Not set
On: Set
Off: Not set
On: Set
• When the Safety CPU is powered on or is
reset
• When an error is cleared
• This relay switches to on if a cycle in which
safety cycle processing was not executed is
detected.
• Once the relay turns on, it remains on even
if the safety cycle processing is performed
each cycle. (To turn off the relay, power off
and on the system or reset the CPU
module).
• This relay stores the CC-Link IE Field
Network safety communication setting
status.
• When safety communications are available
(the relay is on), the start I/O number of the
target module is stored in SD1904.
• This relay stores the CC-Link IE Field
Network safety communication setting
status.
• When safety communications are available
(the relay is on), the start I/O number of the
target module is stored in SD1905.
• This relay stores the CC-Link IE Field
Network safety communication setting
status.
• When safety communications are available
(the relay is on), the start I/O number of the
target module is stored in SD1906.
• This relay stores the CC-Link IE Field
Network safety communication setting
status.
• When safety communications are available
(the relay is on), the start I/O number of the
target module is stored in SD1907.
• This relay stores the CC-Link IE Field
Network safety communication setting
status.
• When safety communications are available
(the relay is on), the start I/O number of the
target module is stored in SD1908.
• This relay stores the CC-Link IE Field
Network safety communication setting
status.
• When safety communications are available
(the relay is on), the start I/O number of the
target module is stored in SD1909.
• This relay stores the CC-Link IE Field
Network safety communication setting
status.
• When safety communications are available
(the relay is on), the start I/O number of the
target module is stored in SD1910.
• This relay stores the CC-Link IE Field
Network safety communication setting
status.
• When safety communications are available
(the relay is on), the start I/O number of the
target module is stored in SD1911.
Set by (setting timing)
CPU
S (Error)
RnSF
S (Status change)
RnPSF
RnSF
S (Initial)
RnPSF
RnSF
S (Initial)
RnPSF
RnSF
S (Initial)
RnPSF
RnSF
S (Initial)
RnPSF
RnSF
S (Initial)
RnPSF
RnSF
S (Initial)
RnPSF
RnSF
S (Initial)
RnPSF
RnSF
S (Initial)
RnPSF
RnSF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents