Sign In
Upload
Manuals
Brands
Emerson Manuals
Transmitter
Rosemount Analytical HART 5081-A-HT
Emerson Rosemount Analytical HART 5081-A-HT Manuals
Manuals and User Guides for Emerson Rosemount Analytical HART 5081-A-HT. We have
1
Emerson Rosemount Analytical HART 5081-A-HT manual available for free PDF download: Instruction Manual
Emerson Rosemount Analytical HART 5081-A-HT Instruction Manual (112 pages)
Two-Wire Chlorine, Dissolved Oxygen, and Ozone Transmitter
Brand:
Emerson
| Category:
Transmitter
| Size: 3.2 MB
Table of Contents
Table of Contents
3
Description and Specifications
7
Features and Applications
7
Specifications - General
8
Specifications - Oxygen
9
Specifications - Free Chlorine
9
Specifications - Total Chlorine
9
Specifications - Ozone
9
Specifications - Percent Oxygen in Gas
9
Transmitter Display During Calibration and Programming
10
Infrared Remote Controller
10
HART Communication
10
Model 5081-A Mounting and Dimensional Drawings
11
Ordering Information
12
Accessories
12
Installation
13
Orienting the Display Board
13
Unpacking and Inspection
13
Mounting the Model 5081-A on a Flat Surface
14
Load/Power Supply Requirements
16
Power Supply/Current Loop
16
Power Supply/Current Loop Wiring
16
Amperometric Sensors with Optimum EMI/RFI Cable or Variopol Cable
17
Amperometric Sensors with Standard Cable
17
Wiring
17
Wiring Model 499A Oxygen, Chlorine, and Ozone Sensors
17
Free Chlorine Sensor with Standard Cable and 399-14 Ph Sensor with Internal
18
Free Chlorine Sensor with Standard Cable and 399VP-09 Ph Sensor Without
18
Internal Preamplifier
18
Wiring Model 499ACL-01 (Free Chlorine) Sensors and Ph Sensors
18
Free Chlorine Sensor with Optimum EMI/RFI Cable or Variopol Cable and
19
Free Chlorine Sensor with Optimum EMI/RFI Cable or Variopol Cable and 399-09-62 Ph Sensor Without Internal Preamplifier
19
Free Chlorine Sensor with Optimum EMI/RFI Cable or Variopol Cable and 399VP-09 Ph Sensor Without Internal Preamplifier
19
Free Chlorine Sensor with Standard Cable and 399-09-62 Ph Sensor Without
19
Hx438 and Gx448 Sensors
20
Intrinsically SAFE and Explosion PROOF INSTALLATIONS
21
Wiring Model Hx438 and Gx448 Sensors
20
Display and OPERATION
29
Display Screens
29
Process Display Screen
29
Program Display Screen
29
Infrared Remote Controller
30
Infrared Remote Controller (IRC) - Key Functions
30
Diagnostic Messages
31
Menu Tree
31
Security
31
Using Hold
31
Menu Tree
32
Operation with Model 275, 375, or 475
33
Connecting the HART Communicator
33
Note on 275, 375, or 475 HART Communicator
33
Operation
34
Menu Tree (HART)
35
Default Settings
39
General
39
Programming
39
PROGRAMMING (Continued)
39
Default Settings
41
Output Ranging
41
Temperature Settings
43
Display
45
Factory Default
47
Hart
47
Calibration Setup
48
Line Frequency
50
Ph Measurement
51
Barometric Pressure
54
Calibration - Temperature
55
Introduction
55
Procedure
56
CALIBRATION - Oxygen
57
Introduction
57
Sensor Current as a Function of Dissolved Oxygen Concentration
57
Procedure - Zeroing the Sensor
58
Procedure - Air Calibration
59
Procedure - In-Process Calibration
60
Calibration - Free Chlorine
61
Introduction
61
Sensor Current as a Function of Free Chlorine Concentration
61
Procedure - Zeroing the Sensor
62
Procedure - Full Scale Calibration
63
Dual Slope Calibration
64
Calibration - Total Chlorine
66
Determination of Total Chlorine
66
Introduction
66
Sensor Current as a Function of Total Chlorine Concentration
66
Procedure - Zeroing the Sensor
67
Procedure - Full Scale Calibration
68
Dual Slope Calibration
69
CALIBRATION - Ozone
71
Introduction
71
Sensor Current as a Function of Ozone Concentration
71
Procedure - Zeroing the Sensor
72
Procedure - Full Scale Calibration
73
CALIBRATION - Ph
74
Calibration Slope and Offset
74
Introduction
74
Procedure - Auto Calibration
75
Procedure - Manual Calibration
76
Standardization
77
Ph Slope Adjustment
78
Calibration - Current Output
79
Current Output Calibration
79
General
79
Procedure
79
Diagnostic Messages for Dissolved Oxygen
80
Diagnostic Messages for Ozone and Total Chlorine
80
Diagnostics
80
General
80
Diagnostic Messages for Free Chlorined
81
Ph Measurement and Calibration Problems
82
Troubleshooting
82
Warning and Fault Messages
82
Troubleshooting When a Warning or Fault Message Is Showing
83
Temperature Measurement and Calibration Problems
87
Oxygen Measurement and Calibration Problems
88
Free Chlorine Measurement and Calibration Problems
90
Total Chlorine Measurement and Calibration Problems
92
Ozone Measurement and Calibration Problems
93
Simulate Chlorine and Ozone
97
Simulate Dissolved Oxygen
97
Simulating Input Currents - Chlorine and Ozone
97
Simulating Input Currents - Dissolved Oxygen
97
Simulate Ph
98
Simulating Inputs - Ph
98
Simulating RTD Inputs
99
Simulating Temperature
99
Three-Wire RTD Configuration
99
Checking for a Poisoned Reference Electrode
100
Measuring Reference Voltage
100
Exploded View of Model 5081-A Transmitter
101
Maintenance
101
Overview
101
Transmitter Maintenance
101
Replacement Parts for Model 5081-A Transmitter
102
Return of Material
103
Barometric Pressure as a Function of Altitude
104
MODEL 4000 PERCENT Oxygen SENSOR for MEASUREMENT in GAS
105
Advertisement
Advertisement
Related Products
Emerson Rosemount 5081-T
Emerson ROSEMOUNT 5081-A
Emerson Rosemount Analytical HART SMART 5081C-HT
Emerson Rosemount 5400 Series
Emerson Rosemount 5408:SIS
Emerson 5301HxxxxxxxxxxxxxxZZ Series
Emerson Rosemount 5302
Emerson Rosemount 5301
Emerson Rosemount 551
Emerson 5303HxxxxxxxxxxxxxxZZ Series
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL