Emerson Rosemount 5408:SIS Reference Manual (260 pages)
Level Transmitters Non-Contacting Radar
Brand:
Emerson
| Category:
Transmitter
| Size: 35 MB
Table of Contents
Table of Contents
5
Chapter 1 Introduction
11
Using this Manual
11
Product Recycling/Disposal
11
Chapter 2 Transmitter Overview
13
Measurement Principle
13
Process Characteristics
14
Dielectric Constant
14
Foam and Turbulence
14
Dust
15
Solid Surface
15
Vessel Characteristics
16
In-Tank Obstructions
16
Tank Shape
16
Application Examples
16
Components of the Transmitter
18
System Integration
20
Chapter 3 Mechanical Installation
23
Safety Messages
23
Confirm Approval Type
23
Installation Considerations
24
Mounting Position
24
Free Space Requirements
25
Antenna Size
26
Antenna Inclination
26
Non-Metallic Tanks
27
Beam Width and Beam Angle
27
Nozzle Requirements
29
Still Pipe/Chamber Installations
31
Ball Valve Installation
34
Mounting Preparations
35
Assemble the Segmented Cone Antenna
35
Shorten the Extended Cone Antenna
36
Mount the Cone Antenna
38
Protective Cap
38
Flanged Version
39
Flanged Version with Air Purge Ring (Option Code PC1)
40
Threaded Version, Antenna Diameter (D) < Thread Diameter (D)
41
Threaded Version, Antenna Diameter (D) > Thread Diameter (D)
44
Bracket Mounting
46
Align Transmitter Head
48
Mount the Process Seal Antenna
50
Flanged Version
50
Tri-Clamp Version
52
Mount the Parabolic Antenna
53
Flanged Version
53
Threaded Version
55
Welded Version
59
Adjust the Inclination of the Antenna
63
Connect the Air Purging
66
Adjust Display Orientation (Optional)
67
Chapter 4 Electrical Installation
69
Safety Messages
69
Cable Selection
69
Cable Gland/Conduit
70
Power Supply
70
Load Limitations
70
Hazardous Areas
70
Wiring Diagram
71
Grounding
72
Connect Wiring and Power up
73
Optional Devices
76
Rosemount ™ 333 HART Tri-Loop
76
Chapter 5 Configuration
79
Safety Messages
79
Overview
79
System Readiness
79
Confirm Correct Device Driver
79
Get Started with Your Preferred Configuration Tool
80
Configuration Tools
80
Rosemount Radar Master Plus
81
AMS Device Manager
81
Field Communicator
82
Confirm HART Revision Capability
82
Switch HART Revision Mode
82
Configure Device Using Guided Setup
83
Configure Using Rosemount Radar Master Plus
83
Configure Using AMS Device Manager
83
Configure Using Field Communicator
83
Verify Level
83
Use Rosemount Radar Master Plus
84
Use AMS Device Manager and Field Communicator
84
Establish Multidrop Communication
85
Use Rosemount Radar Master Plus
85
Use AMS Device Manager
85
Use Field Communicator
85
Use with the Rosemount 333 HART Tri-Loop
85
Chapter 6 Operation
87
LCD Display Screen Messages
87
Startup Screen Sequence
87
Variable Screens
88
Set up the LCD Display
89
Use Rosemount Radar Master Plus
89
Use AMS Device Manager and Field Communicator
89
View Measurement Data
89
Reference Manual
90
Use AMS Device Manager and Field Communicator
90
Interpret Measurement Status
90
Device Status
91
Check Device Status
91
Chapter 7 Service and Troubleshooting
95
Safety Messages
95
Diagnostic Messages
95
Troubleshooting Guide
101
Service and Troubleshooting Tools
107
Using the Echo Curve
107
Managing Disturbance Echoes
111
Perform an Analog Loop Test
117
Use the TEST Terminal
118
Calibrate Analog out
120
Save a Backup File of the Device Configuration
120
Download Configuration from File to Device
121
Restore to Default Settings
121
Use the Simulation Mode
121
View Input Registers
122
View/Edit Holding Registers
122
Write Protect a Transmitter
123
Application Challenges
124
Handling Disturbances at Top of Tank
124
Tracking of Weak Surface Echoes Close to Tank Bottom
126
Handling Ghost Echoes in Still Pipes
129
Handling Strong Double Bounce Echoes
130
Replace the Transmitter Head
132
Cleaning or Replacing the PTFE Sealing
134
Flanged Version
135
Tri Clamp Version
136
Service Support
138
Chapter 8 Safety Instrumented Systems (4-20 Ma Only)
141
Safety Messages
141
Terms and Definitions
141
Safety Instrumented System (SIS) Certification
143
Safety Certified Identification
144
Installation
145
Measuring Range
146
Configuration
146
Prerequisites
146
Configure Device Using Guided Setup
146
Set Operational Mode
146
Enable Safety Mode
147
Alarm and Saturation Levels
147
Site Acceptance
148
Proof-Testing
148
Overview
148
Perform 1-Point Level and Analog Output Verification
149
Perfom 2-Point Level and Analog Output Verification
152
Perform Analog Output Verification
154
Perform Level Deviation Monitoring
154
Product Repair
155
Specifications
155
Failure Rate Data
155
Safety Deviation
155
Transmitter Response Time
155
Diagnostic Test Interval
155
Turn-On Time
155
Appendix A Specifications and Reference Data
157
Performance Specifications
157
General
157
Measuring Range
158
A.1.2 Measuring Range
158
Environment
160
A.1.3 Environment
160
Functional Specifications
161
General
161
Display and Configuration
161
A.2 Functional Specifications
161
4-20 Ma HART
163
Power Consumption
163
Diagnostics
165
A.2.4 Diagnostics
165
Process Temperature and Pressure Rating
166
Temperature Limits
167
Flange Rating
168
A.2.7 Flange Rating
168
Conditions Used for Flange Strength Calculations
169
Air Purging
171
A.2.9 Air Purging
171
System Integration
172
A.2.10 System Integration
172
Physical Specifications
173
Material Selection
173
Engineered Solutions
173
Housing and Enclosure
173
A.3 Physical Specifications
173
Tank Connection
174
Flange Dimensions
174
Antenna Versions
174
Material Exposed to Tank Atmosphere
174
A.3.4 Tank Connection
174
Ordering Information
175
Rosemount 5408 Level Transmitter
175
A.4 Ordering Information
175
Rosemount 5408:SIS Level Transmitter
180
Availability of Process Connections
186
Spare Parts and Accessories
188
Accessories
195
A.6.1 Accessories
195
Dimensional Drawings
196
A.7 Dimensional Drawings
196
A.7.1 Standard Flanges
200
Standard Flanges
200
Appendix B Product Certifications
203
European Directive Information
203
Safety Instrumented Systems (SIS)
203
Telecommunication Compliance
203
Fcc
204
Radio Equipment Directive (RED) 2014/53/EU
205
Installing Equipment in North America
206
U.s.a
206
E5 Explosionproof (XP), Dust-Ignitionproof (DIP)
206
I5 Intrinsic Safety (IS), Non-Incendive (NI)
208
Canada
209
E6 Explosionproof, Dust-Ignitionproof
209
B.9 Canada
209
I6 Intrinsically Safe and Non-Incendive Systems
211
Europe
213
E1 ATEX Flameproof
213
B.10 Europe
213
I1 ATEX Intrinsic Safety
214
N1 ATEX Type N: Non-Sparking
216
International
216
E7 Iecex Flameproof
216
I7 Iecex Intrinsic Safety
217
N7 Iecex Type N: Non-Sparking
219
Brazil
219
E2 INMETRO Flameproof
219
I2 INMETRO Intrinsic Safety
220
N2 INMETRO Type N: Non-Sparking
220
China
221
E3 Flameproof
221
I3 Intrinsic Safety
221
N3 Type N: Non-Sparking
221
B.13 China
221
India
222
Intrinsic Safety
222
Flameproof Safety
222
Intrinsic Safety and Flameproof
222
Republic of Korea
222
IP Intrinsic Safety
222
B.14 India
222
Additional Certifications
223
QT Safety-Certified to IEC 61508:2010 with Certificate of FMEDA Data
223
Suitable for Intended Use
223
U1 Overfill Prevention
223
B.16 Additional Certifications
223
Installation Drawings
224
B.17 Installation Drawings
224
Appendix C Configuration Parameters
231
Menu Tree
231
Device Setup
233
HART Protocol
233
Burst Mode
233
Units
234
Analog Output
234
C.2.2 Units
234
Display
235
Security
235
Write Protection
235
Device Information
236
C.2.6 Device Information
236
Level Setup
237
Geometry
237
C.3 Level Setup
237
Environment
245
C.3.2 Environment
245
Volume
246
Scaled Variable
246
C.3.3 Volume
246
Antenna
247
C.3.5 Antenna
247
Advanced
249
C.3.6 Advanced
249
Alert Setup
255
C.4 Alert Setup
255
C.4.3 High/Low User Defined Alert
256
Advertisement
Emerson Rosemount 5408:SIS Reference Manual (274 pages)
Level Transmitters, Non-Contacting Radar with HART Protocol
Brand:
Emerson
| Category:
Transmitter
| Size: 38 MB
Table of Contents
Table of Contents
5
Chapter 1 Introduction
9
Using this Manual
9
Product Recycling/Disposal
9
Chapter 2 Transmitter Overview
11
Measurement Principle
11
Process Characteristics
12
Vessel Characteristics
14
Application Examples
14
Components of the Transmitter
17
System Integration
18
Chapter 3 Mechanical Installation
21
Safety Messages
21
Confirm Approval Type
21
Installation Considerations
22
Mounting Preparations
32
Mount the Cone Antenna
36
Mount the Process Seal Antenna
49
Mount the Parabolic Antenna
53
Adjust Display Orientation (Optional)
71
Chapter 4 Electrical Installation
73
Safety Messages
73
Hazardous Areas
74
Prepare the Electrical Connections
74
Connect Wiring and Power up
78
Optional Devices
81
Chapter 5 Configuration
83
Safety Messages
83
Overview
83
System Readiness
84
Get Started with Your Preferred Configuration Tool
85
Confirm HART ® Revision Capability
87
Configure Transmitter Using Guided Setup
87
Verify Level
88
Establish Multidrop Communication
90
Use with the Rosemount 333 HART ® Tri-Loop
91
Write Protect a Transmitter
92
Chapter 6 Operation
93
LCD Display Screen Messages
93
Set up the LCD Display
95
View Measurement Data
95
Device Status
97
Chapter 7 Service and Troubleshooting
101
Safety Messages
101
Diagnostic Messages
101
Troubleshooting Guides
107
Service and Troubleshooting Tools
113
Application Challenges
132
Replace the Transmitter Head
139
Cleaning or Replacing the PTFE Sealing
141
Service Support
146
Chapter 8 Safety Instrumented Systems (SIS) Requirements
147
Safety Messages
147
Terms and Definitions
148
Safety Instrumented System (SIS) Certification
149
Safety Certified Identification
151
Installation
152
Configuration
152
Site Acceptance
154
Perform Proof Test for SIS Applications
155
Specifications
161
Appendix A Specifications and Reference Data
163
Performance Specifications
163
Functional Specifications
166
Physical Specifications
177
Ordering Information
180
Availability of Process Connections
191
Spare Parts and Accessories
193
Dimensional Drawings
201
Appendix B Product Certifications
211
European Directive Information
211
Safety Instrumented Systems (SIS)
211
Ordinary Location Certification
211
Telecommunication Compliance
211
Fcc
212
Radio Equipment Directive (RED) 2014/53/EU
213
Installing Equipment in North America
213
Usa
214
Canada
217
Europe
221
International
225
Brazil
228
China
229
Technical Regulations Customs Union (EAC)
230
Japan
233
India
233
Republic of Korea
234
Additional Certifications
235
Installation Drawings
238
Appendix C Configuration Parameters
249
Menu Tree
249
Device Setup
251
Level Setup
255
Alert Setup
271
Emerson Rosemount 5408:SIS Reference Manual (216 pages)
Level Transmitters
Brand:
Emerson
| Category:
Transmitter
| Size: 36 MB
Table of Contents
Table of Contents
5
Chapter 1 Introduction
7
Using this Manual
7
NAMUR NE 53 Revision History
8
Product Certifications
8
Product Recycling/Disposal
8
Chapter 2 Transmitter Overview
9
Measurement Principle
9
Process Characteristics
9
Vessel Characteristics
11
Application Examples
11
Components of the Transmitter
13
System Integration
14
Chapter 3 Mechanical Installation
17
Safety Messages
17
Confirm Approval Type
18
Installation Considerations
18
Mounting Preparations
27
Mount the Cone Antenna
31
Mount the Process Seal Antenna
43
Mount the Parabolic Antenna
47
Adjust Display Orientation (Optional)
64
Chapter 4 Electrical Installation
67
Safety Messages
67
Hazardous Areas
68
Prepare the Electrical Connections
68
Connect Wiring and Power up
71
Optional Devices
75
Chapter 5 Configuration
77
Safety Messages
77
Overview
77
Configuration Tools
77
Confirm Correct Device Driver
78
Rosemount Radar Master Plus
78
Confirm HART ® Revision Capability
79
Configure Transmitter Using Guided Setup
79
Run Verify Level
80
Multidrop Communication
80
Use with the Rosemount 333 HART ® Tri-Loop
80
Write Protect a Transmitter
81
Chapter 6 Operation
83
LCD Display Screen Messages
83
Select the Display Variables
84
View Measurement Data
85
Check Device Status
85
Smart Echo Level Test
88
Service and Troubleshooting
91
Safety Messages
91
Diagnostic Messages Per NAMUR NE 107
92
Troubleshooting Guides
103
Service and Troubleshooting Tools
118
Application Challenges
129
Replace the Transmitter Head
140
Cleaning or Replacing the PTFE Sealing
143
Service Support
147
Appendix A Specifications and Reference Data
149
Performance Specifications
149
Functional Specifications
152
Physical Specifications
161
Spare Parts List - Transmitter Head
163
Spare Parts List - Antenna
168
Availability of Process Connections
175
Accessories
178
Dimensional Drawings
179
Appendix B Configuration Parameters
189
Menu Tree
189
Device Setup
190
Level Setup
194
Alert Setup
212
Advertisement
Emerson Rosemount 5408:SIS Reference Manual (61 pages)
Level Transmitters, Non-Contacting Radar
Brand:
Emerson
| Category:
Transmitter
| Size: 6 MB
Table of Contents
Table of Contents
3
Models Covered
13
Using this Manual
13
Product Recycling/Disposal
14
Measurement Principle
15
Process Characteristics
16
Dielectric Constant
16
Foam and Turbulence
16
Condensation
16
Vessel Characteristics
16
In-Tank Obstructions
16
Tank Shape
17
Application Examples
17
Components of the Transmitter
19
System Integration
20
Safety Messages
21
Review Mounting Considerations
22
Mounting Position
22
Antenna Size
23
Inclination of Antenna
23
Non-Metallic Tanks
23
Beam Width and Beam Angle
24
Nozzle Requirements
25
Free Space Requirements
27
Installation in Still Pipe/Chamber
28
Ball Valve Installation
29
Review Mounting Preparations
30
Assemble the Segmented Cone Antenna
30
Shorten the Extended Cone Antenna
32
Mount the Cone Antenna
33
Flanged Version
34
Flanged Version with Air Purge Ring
35
Threaded Version
37
Bracket Mounting
43
Overview
48
Installation
49
Emerson Rosemount 5408:SIS All-In-One Quick Start Manual (44 pages)
Level Transmitters
Brand:
Emerson
| Category:
Transmitter
| Size: 14 MB
Table of Contents
Table of Contents
2
About this Guide
3
Confirm Approval Type
5
Components of the Parabolic Antenna
6
Mount the Transmitter
8
Adjust the Inclination of the Antenna
21
Connect the Air Purging
25
Adjust Display Orientation (Optional)
27
Prepare the Electrical Connections
28
Connect Wiring and Power up
35
10 Configuration
39
Emerson Rosemount 5408:SIS Quick Start Manual (37 pages)
Level Transmitter
Brand:
Emerson
| Category:
Transmitter
| Size: 7 MB
Table of Contents
About this Guide
2
Confirm Approval Type
4
Mount the Transmitter
5
Bracket Mounting
14
Align Transmitter Head
18
Adjust Display Orientation (Optional)
20
Prepare the Electrical Connections
21
Cable Selection
21
Power Supply
21
Power Consumption
21
Wiring Diagram
23
Connect Wiring and Power up
26
Configure Transmitter Using Guided Setup
30
Assemble the Segmented Cone Antenna
32
Emerson Rosemount 5408:SIS Quick Start Manual (36 pages)
Level Transmitters, Parabolic Antenna
Brand:
Emerson
| Category:
Transmitter
| Size: 12 MB
Table of Contents
Table of Contents
2
About this Guide
3
Confirm Approval Type
5
Components of the Parabolic Antenna
6
Mount the Transmitter
8
Adjust the Inclination of the Antenna
17
Connect the Air Purging
20
Adjust Display Orientation (Optional)
21
Prepare the Electrical Connections
22
Connect Wiring and Power up
29
Configure Transmitter Using Guided Setup
33
Emerson Rosemount 5408:SIS Quick Start Manual (36 pages)
Level Transmitters
Brand:
Emerson
| Category:
Transmitter
| Size: 7 MB
Table of Contents
Table of Contents
2
About this Guide
3
Confirm Approval Type
5
Mount the Transmitter
6
Align Transmitter Head
16
Adjust Display Orientation (Optional)
18
Prepare the Electrical Connections
19
Connect Wiring and Power up
26
Configure Transmitter Using Guided Setup
30
Assemble the Segmented Cone Antenna
32
Emerson Rosemount 5408:SIS Quick Start Manual (36 pages)
Cone Antenna
Brand:
Emerson
| Category:
Antenna
| Size: 7 MB
Table of Contents
Table of Contents
2
About this Guide
3
Confirm Approval Type
5
Mount the Transmitter
6
Align Transmitter Head
18
Adjust Display Orientation (Optional)
20
Prepare the Electrical Connections
21
Connect Wiring and Power up
28
Configuration
32
Assemble the Segmented Cone Antenna
34
Emerson Rosemount 5408:SIS Quick Start Manual (20 pages)
Process Seal Antenna
Brand:
Emerson
| Category:
Transmitter
| Size: 5 MB
Table of Contents
Table of Contents
3
Confirm Approval Type
3
Mount the Transmitter
4
Align Transmitter Head
8
Adjust Display Orientation (Optional)
10
Prepare the Electrical Connections
11
Connect Wiring and Power up
12
Configure Transmitter Using Guided Setup
17
Advertisement
Related Products
Emerson Rosemount 5400 Series
Emerson Rosemount 5081-T
Emerson Micro Motion 5700
Emerson 5302HxxxxxxxxxxxxxxZZ Series
Emerson 5303HxxxxxxxxxxxxxxZZ Series
Emerson Rosemount 5301
Emerson Rosemount 5303
Emerson ROSEMOUNT 5081-A
Emerson Rosemount Analytical HART 5081-A-HT
Emerson Rosemount Analytical HART SMART 5081C-HT
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL