Procedure
Milling
Operating Manual, 03/2013, 6FC5398-7CP40-3BA1
1.
Select the "Machine" operating area and press the <JOG> key.
2.
Press the "Workpiece zero" softkey.
3.
Press the "Rectangular spigot" softkey.
- OR -
Press the "1 circular spigot" softkey.
- OR -
If these softkeys are not listed, press any vertical softkey (with the
exception of "Set edge") and in the drop-down list, select the desired
measurement version.
4.
Select "Measuring only" if you only want to display the measured values.
- OR -
Select the desired zero offset in which you want to store the zero point
(e.g. basis reference).
- OR -
Press the "Select ZO" softkey and select the zero offset in which the
zero point is to be saved in the "Zero Offset – G54 ... G599" window and
press the "In manual" softkey.
You return to the "1 Circular Spigot" window.
The selection of zero offsets can differ.
Please refer to the machine manufacturer's specifications.
5.
Specify the position setpoints (X0/Y0) of the spigot center point P0.
6.
Traverse the tool to the first measuring point.
7.
Press the "Save P1" softkey.
The point is measured and stored.
Setting up the machine
2.6 Measuring the workpiece zero
103