CDM-570/570L Satellite Modem with Optional IP Module
Front Panel Operation
If the measured values are greater than, or equal to 16.0 dB, the display will show
16.0 dB.
If AUPC is not enabled, the values of maximum and average TPLI will both
show 'Off'.
Examples:
08.0, 13.5, 2.5, 1.8 means:
Minimum Eb/No observed in the measurement interval = 8.0 dB
Average Eb/No observed in the measurement interval = 13.5 dB
Maximum TPLI observed in the measurement interval = 2.5 dB
Average TPLI observed in the measurement interval = 1.8 dB
Loss, 04.5, Off, Off means:
There was a loss of demod lock during the measurement interval
Average Eb/No observed in the measurement interval = 4.5 dB
Maximum TPLI observed in the measurement interval = AUPC disabled
Average TPLI observed in the measurement interval = AUPC disabled
(MONIT, STATS) CLEAR
If the user selects Clear-All, the following screen is displayed:
Clear all Stored Stats?
(▲ ▼, ENTER)
No
Yes
If the user selects Yes, the Statistics log is cleared, and the user is taken directly
back to the previous menu.
(MONIT, STATS) CONFIGURE
If the users selects Configure, the following sub-menu is displayed:
Stats Logging Interval:
(▲ ▼,ENTER)
Disabled
The user is prompted to enter the logging interval (the period of time over which
the statistics will be measured), using the
The user can choose Disabled, 10, 20, 30, 40, 50, 60, 70, 80, or 90 minutes.
Stats Logging Interval:
30 minutes
▲ ▼
(▲ ▼,ENTER)
6–45
MN/CDM570L.IOM
arrow keys, then press ENTER.