CDM-570/570L Satellite Modem with Optional IP Module
Serial Remote Control
Command
Arguments
Parameter
(Instruction
for Command
Type
Code and
or Response
Qualifier)
Rx Frequency
RFQ=
9 bytes
Rx FEC Type
RFT=
1 byte, value
of 0 thru 6
Rx Demod
RMD=
1 byte, value
type
of 0 thru 5
Description of Arguments
to Query
Command or Query.
Rx Frequency
CDM-570L: 950 to 1950 MHz
CDM-570: 50 to 90 and 100 - 180 MHz
Resolution=100 Hz
Example: RFQ=0950.9872
Example: RFQ=0073.4528
Command or Query.
Rx FEC Type, where:
0=None (uncoded – no FEC) with differential encoding ON
1=Viterbi
2=Viterbi + Reed-Solomon
3= Reserved – do not use
4= Reserved – do not use
5=TCM + Reed-Solomon
6=Turbo
7= TPC/LDPC (Future option)
Example: RFT=1 (which is Viterbi only)
Command or Query.
Rx Demodulation, where:
0=BPSK
1=QPSK
2=OQPSK
3=8PSK
4=16QAM (Turbo or Viterbi + RS only)
5=8-QAM (Future option)
Depending on FEC type, not all of these selections will be valid.
All other codes are invalid.
Example: RMD=2 (selects OQPSK)
Response to
Command
RFQ=
RFQ?
RFQ*
RFQ#
RFT=
RFT?
RFT*
RFT#
RFT+
RMD=
RMD?
RMD*
RMD#
RMD+
13–12
Revision 3
MN/CDM570L.IOM
Query
(Instruction
Response to Query
Code and
Qualifier)
RFQ?
RFQ=xxxx.xxxx
(see description of
arguments)
RFT?
RFT=x
(same format
as command argument)
RMD?
RMD=x
(see description of
arguments)