Comtech EF Data CDM-570 Installation And Operation Manual page 390

70/140mhz, l-band,
Hide thumbs Also See for CDM-570:
Table of Contents

Advertisement

Command
Arguments
Parameter
(Instruction
for Command
Type
Code and
or Response
Qualifier)
Outdoor Unit
ODU=
1 byte, value
Comms Enable
of 0 or 1
Front Panel
FPL=
1 byte, value
Lockout
of 0 or 1
Local/Remote
LRS=
1 byte, value
Status
of 0 or 1
Description of Arguments
to Query
Command or Query. CDM-570 Only
Enables or disables communications, via the FSK link, with a
Comtech EF Data transceiver (ODU), where:
0=Disabled
1=Enabled
Example: ODU=0 (selects Disabled)
Command or query.
Control the state of front-panel lockout, where:
0 = no lockout
1 = front panel lockout active.
Disable the lockout by either FPL=0, or by setting into local mode
using LRS=0 (response is LRS+ meaning FPL is disabled at the
same time).
Command or Query.
Local/Remote status, where:
0=Local
1=Serial Remote
3 = Ethernet Remote
Example: LRS=1 (which is Serial Remote)
Update for Remote Commands and Front
Panel Ethernet Menus
Query
Response to
(Instruction
Command
Code and
Qualifier)
ODU=
ODU?
ODU?
ODU*
ODU#
FPL=
FPL?
FPL?
FPL*
FPL#
LRS=
LRS?
LRS?
LRS*
LRS#
LRS+
5
Response to Query
ODU=x
(see description of
arguments)
FPL=x
(see description of
arguments)
LRS=x
(see description of
arguments)