4.8.14 lldp config chassis admin-state

Configure the LLDP/IEEE802.1AB functionality on this device. If disabled,
the LLDP protocol will become inactive, but the LLDP MIBs can still be
accessed.
D
off: Disable the LLDP/IEEE802.1AB functionality.
D
on: Enable the LLDP/IEEE802.1AB functionality.
The default setting is on.
Format
lldp config chassis admin-state {off|on}
Mode
Global Config

4.8.15 lldp config chassis notification-interval

Configure the LLDP minimum notification interval (the minimum time after a
notification trap has been sent until a new trap can be sent, unit: seconds,
min.: 5 sec., max.: 3600 sec., default: 5 sec.).
Format
lldp config chassis notification-interval
Mode
Global Config
CLI L2B