Show Trapflags - Hirschmann RS20 Reference Manual

Industrial, gigabit
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

CLI Commands: Base

4.3.14 show trapflags

This command displays trap conditions. Configure which traps the switch
should generate by enabling or disabling the trap condition. If a trap condition
is enabled and the condition is detected, the switch's SNMP agent sends the
trap to all enabled trap receivers. The switch does not have to be reset to im-
plement the changes. Cold and warm start traps are always generated and
cannot be disabled.
Format
show trapflags
Mode
Privileged EXEC and User EXEC
Authentication Flag
May be enabled or disabled. The factory default is enabled. Indicates
whether authentication failure traps will be sent.
Chassis
Indicates whether traps that are related to the chassis functionality of
the switch will be sent. These functions include the signal contacts,
the ACA, warnings about the temperature, changes in the module
map, addition or removal of SFP modules, power failure and the
LLDP and SNTP features. May be enabled or disabled.
Default: enabled.
Layer 2 Redundancy
Indicates whether traps that are related to the layer 2 redundancy
features of the switch will be sent. The HiPER-Ring and the
Redundant Coupling will tell you with these traps when the main line
has failed or returned. May be enabled or disabled.
Default: enabled.
Link Up/Down Flag
May be enabled or disabled. The factory default is enabled. Indicates
whether link status traps will be sent.
Multiple Users Flag
May be enabled or disabled. The factory default is enabled. Indicates
whether a trap will be sent when the same user ID is logged into the
switch more than once at the same time (either via telnet or serial
port).