1.5.1

Device state

FAULT
RM
Sb
P
These LEDs provide information about conditions which affect the operation
of the whole device.
The following table applies to the stated device variants only:
MACH104-20TX-FR...
LED
Display
P
Supply
voltage
The following table applies to the stated device variants only:
MACH104-20TX-F...
MACH104-20TX-F-4-PoE...
LED
Display
P
Supply
voltage
The following table applies to every device variant:
LED
Display
Sb
Stand-by
FAULT Signal
contact
RM
Ring
Manager
Installation MACH104
Release 08 01/2019
Color
Activity
none
green
lights up
yellow
lights up
Color
Activity
none
green
lights up
Color
Activity
none
green
lights up
none
red
lights up
none
green
lights up
flashing
yellow
lights up
Meaning
Supply voltages 1 and 2 are too low.
Supply voltage 1 and 2 is on
Supply voltage 1 or 2 is on
Meaning
Supply voltage is too low
Supply voltage is on
Meaning
Stand-by mode not enabled
Standby mode enabled
The signal contact is closed, it is not
reporting any detected errors.
The signal contact is open - it is reporting a
detected error.
The RM function is deactivated.
The RM function is active.
The redundant port is disabled.
The device detects an incorrect
configuration of the HIPER-Ring (for
example the ring is not connected to the ring
port).
The RM function is active.
The redundant port is enabled.