Lldp Config Chassis Tx-Hold-Mult; Lldp Chassis Tx-Interval - Hirschmann RS20 Reference Manual

Industrial, gigabit
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

4.8.18 lldp config chassis tx-hold-mult

Configure the LLDP transmit hold multiplier, a time-to-live value expressed
as a multiple of the LLDP Message Tx Interval (tx-interval), min.: 2, max.: 10,
default: 4.
Format
lldp config chassis tx-hold-mult
Mode
Global Config

4.8.19 lldp chassis tx-interval

Configure the interval at which LLDP frames are transmitted on behalf of this
LLDP agent (unit: seconds, min.: 5 sec., max.: 32768 sec., default: 30 sec.)
Format
lldp chassis tx-interval
Mode
Global Config
CLI L2B
Release 4.0 11/07
4.8 LLDP - Link Layer Discovery Protocol