Hirschmann RS20 Reference Manual page 142

Industrial, gigabit
Hide thumbs Also See for RS20:
Table of Contents

Advertisement

{mode {auto|device-status|manual}
|monitor {aca-removal|all|connection-error
|fan-broken|module-removal
|power-supply-1| power-supply-2
|power-supply-3-1|power-supply-3-2
|power-supply-4-1|power-supply-4-2
|temperature} {disable|enable}
|state {closed|open}
|trap {disable|enable} }
Mode
Global Config
Contact No.
Selection of the signal contact:
– 1 signal contact 1,
– 2 signal contact 2,
– all signal contact 1 and signal contact 2.
mode
Selection of the operational mode:
– auto function monitoring,
– device-status the device-status determines the signal con-
tact´s status.
– manual manually setting the signal contact.
monitor
Enables or disables the monitoring of the selected event or all events.
– enable monitoring,
– disable no monitoring.
state
Set the manual setting of the signal contact:
– closed ,
– open.
Only takes immediate effect in manual mode.
trap
Configures the sending of traps concerning the signal contact.
– enable enables sending traps,
– disable disables sending traps.
142
4.7 System Utilities
CLI L2B
Release 4.0 11/07

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents