4.7.18 temperature

This command configures the lower and upper temperature limit for the
device. If these limits are exceeded, a trap is sent. The unit for the
temperature limit is °C (Celsius), the minimum value is -99, the maximum val-
ue is 99. The default for the lower limit is 0, for the upper limit, it is 70.
Note: to give the temperature in Fahrenheit, use the suffix f.
Format
temperature {lower-limit|upper-limit} <temperature
value> [{c|f}]
Mode
Global Config
lower-limit
Configure the lower temperature limit.
lower-upper
Configure the upper temperature limit.

4.7.19 reboot

This command resets the switch (cold start,
Reset means that all network connections are terminated and the boot code
executes. The switch uses the stored configuration to initialize the switch.
You are prompted to confirm that the reset should proceed. A successful
reset is indicated by the LEDs on the switch.
Format
reboot
Mode
Privileged EXEC
CLI L2B
Release 4.0 11/07
4.7 System Utilities
See "reload" on page
144).