142
Merlin PLUS WNET Manual v2.0
POTS Config Settings
The default POTS Answer module Config settings, which can be viewed in the POTS Answer
panel are:
·
Tieline Codecs Session Data.
·
The Other algorithm.
This configuration will accept the settings from an incoming Tieline codec when it dials with
session data enabled. It will also allow the codec to answer a call from a Comrex POTS codec
supporting the Other algorithm setting.
To reset POTS answering to default settings click the Options symbol in the top right-hand corner
of the panel and select Reset all to factory defaults.
Answering Calls from Non-Tieline POTS Codecs
1. Open the HTML5 Toolbox Web-GUI and click Transport and then POTS Answer.
2. Click the Edit button to configure settings.
3. Select the Sessionless Only check-box when only non-Tieline codecs are dialing a Tieline
codec over POTS. This allows you to select the default encoding setting and Route the
incoming call to a nominated audio stream via a corresponding Answer Route in the answering
codec program if required.
© Tieline Pty. Ltd. 2017