2Nd Pe Sensor; Removing The 2Nd Pe Sensor - Epson Stylus Pro 4910 Service Manual

Large format color inkjet printers
Hide thumbs Also See for Stylus Pro 4910:
Table of Contents

Advertisement

Epson Stylus Pro 4900/Epson Stylus Pro 4910

3.4.5.7 2nd PE Sensor

1.
Remove the Front Cover.
(p142)
2.
Remove the Right Upper Cover.
3.
Remove the Control Panel Cover.
4.
Remove the Right Cover.
(p139)
5.
Remove the Mid-Right Cover/Mid-Left Cover.
6.
Remove the Rear Cover.
(p144)
7.
Remove the Rear Unit.
(p145)
8.
Remove the Printer Cover.
(p133)
9.
Remove the upper rear cover.
(Step 7
195))
10. Disengage the two hooks that secure the "PAPER GUIDE,REAR", and pull the
"PAPER GUIDE,REAR" to remove.
Figure 3-109. Removing the "PAPER GUIDE,REAR"
DISASSEMBLY & ASSEMBLY
(p138)
(p136)
(p150)
in "3.4.5.9 Paper Thickness Sensor1, 2"
Hooks
"PAPER GUIDE,REAR"
Disassembly and Assembly Procedure
11. Disconnect the connector from the 2nd PE Sensor.
12. Disengage the hook, and remove the 2nd PE Sensor.
- Back side of "PAPER GUIDE,REAR" -
Connector
(P.
Figure 3-110. Removing the 2nd PE Sensor
2nd PE Sensor
Hook
Revision A