Release Motor Assy; Removing The Release Motor Assy - Epson Stylus Pro 4910 Service Manual

Large format color inkjet printers
Hide thumbs Also See for Stylus Pro 4910:
Table of Contents

Advertisement

Epson Stylus Pro 4900/Epson Stylus Pro 4910

3.4.5.10 Release Motor Assy

1.
Remove the Front Cover.
(p142)
2.
Remove the Left Cover.
(p137)
3.
Remove the Rear Cover.
(p144)
4.
Disconnect the two connectors (CN305, CN307) from the SUB-C Board.
5.
Release the harnesses from the two clamps.
6.
Disconnect the FFC from the encoder.
7.
Remove the two screws that secure the motor mounting plate, and remove the
motor mounting plate.
A) Silver, Phillips, Bind machine screw M3x6: two pieces
A
- Rear left -
Motor mounting plate
A
CN307
SUB-C Board
Figure 3-116. Disconnecting the connectors
DISASSEMBLY & ASSEMBLY
Encoder
FFC
Clamps
CN305
Disassembly and Assembly Procedure
When removing the Release Motor Assy in the next step, be careful
C A U T I O N
not to damage the scale.
8.
Remove the two screws that secure the Release Motor Assy, and remove the
Release Motor Assy.
B) Silver, Phillips, Pan machine screw M2.6x3: two pieces
When installing the Release Motor Assy, be careful of the
installation direction referring to
Motor mounting plate
B
Figure 3-117. Removing the Release Motor Assy
Revision A
Figure
3-117.
Scale
B
Release Motor Assy
Confidential
197

Hide quick links:

Advertisement