Epson Stylus Pro 4900/Epson Stylus Pro 4910
3.4.5.11 Release Sensor
1.
Remove the Front Cover.
(p142)
2.
Remove the Left Cover.
(p137)
3.
Remove the Rear Cover.
(p144)
4.
Rotate the gear of the Release Motor Assy until the cutout of the shading plate
comes between the Release Sensor's detector section.
- Left rear -
Shading plate
Removable
Release Sensor
Shading plate
Figure 3-118. Rotating the Shading Plate
DISASSEMBLY & ASSEMBLY
Gear
Release Motor Assy
Release Sensor
Unremovable
Disassembly and Assembly Procedure
5.
Disengage the hooks that secure the Release Sensor, and remove the Release
Sensor.
6.
Disconnect the connector from the Release Sensor.
- Left rear -
Hooks
Figure 3-119. Removing the Release Sensor
Revision A
Release Sensor
Connector
198
Confidential