Epson Stylus Pro 4900/Epson Stylus Pro 4910
3.4.6 ASF Unit
3.4.6.1 ASF Motor Assy
1.
Remove the Front Cover.
(p142)
2.
Remove the Left Cover.
(p137)
3.
Remove the Rear Cover.
(p144)
4.
Disconnect the connector from the ASF Motor Assy.
5.
Remove the two screws that secure the ASF Motor Assy, and remove the ASF
Motor Assy.
A) Silver, Phillips, Round Washer Head S-tite M3x5: two pieces
Be sure to refer to Chapter 4 "Adjustment"
A D J U S T M E N T
R E Q U I R E D
specified adjustment after replacing the ASF Motor Assy.
<Adjustment item>
Counter Reset (ASF Motor Assy Counter)
DISASSEMBLY & ASSEMBLY
(see p277)
and perform
Disassembly and Assembly Procedure
- Rear left -
Connector
ASF Motor Assy
Figure 3-123. Removing the ASF Motor Assy
Revision A
A
202
Confidential