3.2.10.4 Front/Rear PE (Paper End) Sensor Removal
1.
Remove the printer mechanism unit. (Refer to 3.2.6.)
2.
Using the tweezers, release the tabs mounting the Front/Rear PE sensors to the rear paper guide at the
bottom of the printer mechanism unit.
3.
Disconnect the connector cables for the PE sensor from the PE sensor connectors.
Connector Cable
for the Front PE Sensor
Figure 3-16. Front/Rear PE Sensor Removal
Rear Paper Guide Assembly
Connector Cable
for the Rear PE Sensor
Rear PE Sensor
Tabs
Front PE Sensor
Disassembly and Assembly