Epson Stylus Pro 4900/Epson Stylus Pro 4910
4.10.7 Active Damper Adjustment
EXECUTION MODE
Normal Mode
PROCEDURE
1.
When any paper is loaded, remove it.
2.
Turn the printer ON.
3.
Start the Service Program and select
4.
Click [Run] to execute the calibration of the CR active damper.
It takes about two minutes and 30 seconds to get the result of this
C H E C K
P O I N T
adjustment.
5.
If
Adjustment Successful
appears, click [OK].
6.
Click [Finish].
7.
Turn the printer OFF to complete the adjustment.
ADJUSTMENT
Active Damper
Adjustment.
CR Related Check & Adjustments
Figure 4-34. Active Damper Adjustment
Revision A
329
Confidential