3.4.12.7 Backing Sensor

1.
Remove the Color Measurement Device.
2.
Remove the Mounter.
(p132)
3.
Remove the backing and the white calibration tile.
4.
Remove the Upper Cover.
(p257)
5.
Open the Front Cover, and move the carriage to the right.
(Step 6
in "3.4.12.5 Paper Pressing Motor"
6.
Disconnect the connector (CN15) from the Main-C Board.
7.
Release the harness from the clamp, and pull it out in the direction of the arrow.
Use tweezers or a similar tool to connect the connector (CN15).
DISASSEMBLY & ASSEMBLY
(p255)
(p256)
(P.
269))
Disassembly and Assembly Procedure
Clamp
Figure 3-215. Pulling out the harness
Revision A
Main-C Board
CN15