Set Ethernet-Oam Port Link-Monitor Symbol-Period - Zte ZXR10 2900E Series Command Reference Manual

Easy-maintenance secure switch
Hide thumbs Also See for ZXR10 2900E Series:
Table of Contents

Advertisement

Default
The link monitoring function is disabled.
Example
The following example enables the link monitoring function on port 1:
zte(cfg)#set ethernet-oam port 1 link-monitor enable

4.30.8 set ethernet-oam port link-monitor symbol-period

Purpose
This command sets the symbol period event of link monitoring.
Command Mode
Global configuration mode
Syntax
set ethernet-oam port <portlist> link-monitor symbol-period threshold <1-65535> wind
ow <1-65535>
Parameter Description
Parameter
<portlist>
threshold <1-65535>
window <1-65535>
Guidelines
The symbol period is determined by the number of symbols collected by the switch within
a specified time period. That is, when a certain number of symbols is collected, a period
is finished. A link alarm event occurs if the number of the collected incorrect symbols
exceeds the threshold value ruled by the period.
Default
The number of incorrect symbols collected in a unit period is 1.
The period of symbol numbers is 1.
The period of symbol numbers
The following example sets the number of the incorrect symbols collected in a unit time to
1 and the symbol period to 30:
SJ-20130731155059-003|2013-11-27 (R1.0)
Description
Port list.
Number of incorrect symbols collected in a unit period.
Period of symbol amounts. The unit is millions. For example, 30
means that a period is every 30 millions symbols are collected.
4-491
Chapter 4 Service Configuration
ZTE Proprietary and Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents