7.2.11 Removing 2.5-inch HDD/SSD modules

I
PCIe SSDs SFF are mounted in the same frames as the 2.5-inch
HDD/SSD modules. Therefore, this section is also valid and applicable if
PCIe SSDs SFF are used.
The preliminary and concluding steps are only necessary for HDD/SSD
modules, not for the PCIe SSDs SFF. PCIe SSDs SFF are never
combined in a RAID array.
Customer Replaceable Unit
(CRU)
Tools: tool-less

7.2.11.1 Preliminary steps

Ê If the HDD/SSD module to be removed is combined into a RAID array,
please proceed as follows:
RAID level
RAID 0
RAID 1
RAID 5
TX2560 M2 / RX2560 M2
Hard disk drive (HDD) / solid state drive (SSD)
Procedure
Only remove an HDD module combined in a RAID 0 array if
defective.
V
CAUTION!
Removing an operational HDD module will result
in data loss!
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section
rebuild" on page
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Performing a RAID array
137.
175