4.4
Getting access to the component
V
CAUTION!
Only for non-hot plug components:
●
Before removing or attaching covers, turn off the server, all peripheral
devices, and any other connected devices. Because there is a risk of
electric shock or damage, please disconnect all power cords from the
outlet.
In order to comply with applicable EMC regulations (regulations on
●
electromagnetic compatibility) and satisfy cooling requirements, the
server must not run while the top/side cover is removed.
For further safety information, please refer to chapter
●
information" on page
Only valid for the TX2560 M2: Don't lift the server by its front cover.
●
There is a possibility that the HDD bay cover hook may break.
4.4.1
Rack server (RX2560 M2)
4.4.1.1
Extending the server out of the rack
V
CAUTION!
Use the anti-tilt plate to prevent the rack from tipping when installing
●
the rack. Pulling the server out of the rack without having installed the
anti-tilt plate may cause the rack to tip over.
Be careful not to pinch fingers or clothes when sliding out the server
●
or pushing it back. Failure to do so may cause injury.
For further safety information, please refer to chapter
●
information" on page
TX2560 M2 / RX2560 M2
43.
43.
Upgrade and Maintenance Manual
Basic hardware procedures
"Important
"Important
61