11.3.1 Preliminary steps
"Suspending BitLocker functionality" on page 111
Ê
"Disabling SVOM boot watchdog functionality" on page 112
Ê
"Shutting down the server" on page 58
Ê
"Disconnecting the power cord" on page 59
Ê
"Getting access to the component" on page 61
Ê
"Removing the system air duct" on page 91
Ê
11.3.2 Removing a CPU
I
This description applies to the following procedures:
– Removing CPU 2 from a 2 CPU configuration
– Removing CPUs from a defective system board
Ê Remove the desired heat sink as described in section
sinks" on page
Figure 273: Opening socket release lever (marked Open 1st)
Ê Unlatch the socket release lever marked Open 1st by pushing it down and
towards the socket (1).
Ê The socket release lever will slightly lift up (2).
TX2560 M2 / RX2560 M2
387.
Upgrade and Maintenance Manual
Processor (CPU)
"Removing heat
377