Fujitsu PRIMERGY RX2560 M2 Upgrade And Maintenance Manual page 197

Hide thumbs Also See for PRIMERGY RX2560 M2:
Table of Contents

Advertisement

I
Further information see cabling plan
HDDs and SAS 3.0 expander board A3C40176099" on page 517
"Options: OOB for six HDD backplanes and PSAS HBA" on
page
530.
I
Connecting SAS cables:
The SAS cables will be connected after installing the SAS expander
holder.
Installing the SAS expander holder
Figure 112: Installing the SAS expander holder (A)
Ê Align the SAS expander holder at a right angle to the HDD cage as shown.
Ê Ensure that the SAS expander board is flush with the SAS backplanes
below.
Ê Lower the SAS expander holder onto the HDD cage, so that the two latches
on each side of the holder engage with the slots on the HDD cage (see
close-up).
TX2560 M2 / RX2560 M2
Hard disk drive (HDD) / solid state drive (SSD)
Upgrade and Maintenance Manual
"Power cabling: 24x/32x 2.5"
and
197