Processor (CPU)
11.4
Upgrading or replacing CPUs
Field Replaceable Unit
(FRU)
Tools: – Phillips PH2 / (+) No. 2 screw driver
– nut driver size 6mm
V
CAUTION!
CPUs are extremely sensitive to electrostatic discharge and must be
handled with care. After a CPU has been removed from its protective
sleeve or from its socket, place it upside down on a nonconducting,
antistatic surface. Never push a CPU over a surface.
11.4.1 Preliminary steps
"Suspending BitLocker functionality" on page 111
Ê
"Disabling SVOM boot watchdog functionality" on page 112
Ê
"Locating the defective server" on page 55
Ê
"Shutting down the server" on page 58
Ê
"Disconnecting the power cord" on page 59
Ê
"Getting access to the component" on page 61
Ê
"Removing the system air duct" on page 91
Ê
"Removing heat sinks" on page 387
Ê
11.4.2 Upgrading or replacing a CPU
11.4.2.1 Removing the CPU
Ê Remove the CPU as described in section
382
Upgrade and Maintenance Manual
Hardware: 15 minutes
Software: 5 minutes
(if applicable)
"Removing a CPU" on page
TX2560 M2 / RX2560 M2
377.