Figure 271: Closing socket release lever and removing protective socket cover
Ê Close the socket release lever marked Close 1st (1) and latch it under the
load plate retention tab to lock down the load plate (2).
Ê When closing the load plate, the protective socket cover will automatically
detach (3).
Ê Remove the socket cover and save it for future use.
V
CAUTION!
Always replace the socket cover if you remove the CPU from the socket!
Figure 272: Closing socket release lever (marked Open 1st)
Ê Close the socket release lever marked Open 1st (1) and latch it under the
load plate retention tab (2).
Ê If applicable, install the second CPU accordingly.
TX2560 M2 / RX2560 M2
Upgrade and Maintenance Manual
Processor (CPU)
375