Indicators On The Hot-Plug Hdd/Ssd Module - Fujitsu PRIMERGY RX2560 M2 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2560 M2:
Table of Contents

Advertisement

Appendix

17.2.2.3 Indicators on the hot-plug HDD/SSD module

Figure 426: Indicators on the hot-plug HDD/SSD module
Pos.
Label
1
2
558
Indicator
Status
off
Access
indicator
green on
off
orange on
Error
indicator
orange
flashing
slowly
Upgrade and Maintenance Manual
Description
The HDD/SSD is inactive.
The HDD/SSD being accessed
No HDD/SSD error detected.
An HDD/SSD error has been
detected.
Possible causes:
– The drive is defective and needs
replacing.
– A RAID rebuild process has
failed.
– The HDD/SSD module has not
been inserted correctly.
HDD/SSD RAID rebuild is in
progress. Data is being restored
after replacing a drive that has been
combined into a RAID array.
TX2560 M2 / RX2560 M2