Removing A 2.5-Inch Hdd/Ssd Module - Fujitsu PRIMERGY RX2560 M2 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2560 M2:
Table of Contents

Advertisement

Hard disk drive (HDD) / solid state drive (SSD)
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V
CAUTION!
All data on all HDDs/SSDs in the RAID array will be lost when deleting
a RAID array! Be sure to back up your data before deleting a RAID
array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Ê When working on a tower server, open the HDD bay cover as described in
section
"Removing accessible drive and HDD bay covers" on page

7.2.11.2 Removing a 2.5-inch HDD/SSD module

Ê Pinch the green locking clips and open the locking lever (see
page
174).
Ê Pull the HDD/SSD module out a few centimeters.
Ê Wait about 30 seconds to allow the HDD to spin down.
I
This is not necessary when removing an SSD.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Ê Pull the HDD/SSD module completely out of its bay.
176
Upgrade and Maintenance Manual
71.
figure 88 on
TX2560 M2 / RX2560 M2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy tx2560 m2

Table of Contents