Ricoh A230 Service Manual page 867

Hide thumbs Also See for A230:
Table of Contents

Advertisement

Bit Switch 03
No.
FUNCTION
0
Amount of protocol dump
data in one protocol dump
list
0: Last communication only
1: Up to the limit of the
memory area for protocol
dumping
1
Not used
to
7
Bit Switch 04
No.
FUNCTION
0
Not used
to
4
5
RCBCTR
0: Not valid 1: Valid
6
Not used
7
Bit Switch 05
No.
FUNCTION
0
Not used
1
Logical channel number
(LCN)
0: Not controlled
1: Fixed at 01
2
Protocol ID check
0: Yes 1: No
3
Not used
to
7
SM
COMMENTS
Change this bit to 0 if you want to have a protocol
dump list of the last communication only.
This bit is only effective for the dump list #2 (D +
Bch1).
Do not change the factory settings.
COMMENTS
Do not change the factory settings.
This bit is used in Germany; set it to 1 for German
PTT approval tests.
1: RCBCTR counts consecutive R:RNR signals. If
the counter reaches the value of N2, the link is
disconnected.
Do not change the factory settings.
COMMENTS
Do not change the factory setting.
This bit is normally 0. However, some networks
may require a fixed LCN. In such cases, this bit
should be 1, and you may have to set a different
value for the LCN using G4 Parameter Switch A.
The Protocol ID is in the CR packet.
Do not change the factory settings.
2-3
BIT SWITCHES
A230/A231/A232

Advertisement

Table of Contents
loading

This manual is also suitable for:

A231A232

Table of Contents