FUSING
6.7.4 CLEANING ROLLER
[B]
[D]
1. Remove the fusing unit.
2. Remove the fusing entrance guide [A] (2 screws).
NOTE: The standard position of the fusing entrance guide is the upper
position, using the lower screw holes [B]
3. Remove the lower fusing cover [C] (1 screw).
NOTE: When removing the lower fusing cover, be careful not to drop the
cleaning roller onto the hot roller.
4. Replace the cleaning roller [D].
A230/A231/A232
[C]
[A]
6-42
Rev. 05/99
A230R604.PCX