SERVICE PROGRAM MODE
Class 1
Class 3
and 2
-907
5-914
5-915
5-920*
5-990
1
2
3
4
5
6
A230/A231/A232
Mode No.
Plug & Play Brand
Name and
Production Name
Setting
Printer Counter
Display
Mechanical
Counter Detection
Recovery Time for
Low Power Mode
SMC Printing
(All Data)
SMC Printing
(SP Mode Data)
SMC Printing
(UP Mode Data)
SMC Printing
(Machine Status
Data)
SMC Printing
(UP Mode - Copy)
SMC Printing
(Large Font Size)
Function
Selects the brand name and the
production name for Windows 95 Plug
& Play. This information is stored in the
NVRAM. If the NVRAM is defective,
these names should be registered
again.
After selecting, press the "Original
Type" key and
at the same time. If
the setting is completed, a "*" mark will
be displayed before the selection.
Selects whether or not the total printer
counter is displayed in the UP mode.
Checks whether the mechanical
counter inside the inner cover is
connected or not.
The default recovery time is 20s
(machine temp. 145 to 157C). Since
recovery starts at a higher temperature
with this setting, it provides the machine
more leeway in reaching the ready
status temperature on time.
Prints all the system parameter lists.
See the "System Parameter and Data
Lists" section for how to print the lists.
Prints the SP mode data list.
See the "System Parameter and Data
Lists" section for how to print the lists.
Prints the UP mode data list.
See the "System Parameter and Data
Lists" section for how to print the lists.
Prints the machine status history data
list.
See the "System Parameter and Data
Lists" section for how to print the lists.
Prints the Copy Mode list (UP Mode
No.10)
See the "System Parameter and Data
Lists" section for how to print the lists.
Prints the SP mode data list with a large
font size.
See the "System Parameter and Data
Lists" section for how to print the lists.
This SP mode is used when the SMC
list is sent by fax to the number stored
with SP5-812.
4-36
Rev. 01/2000
Settings
0: No
1: Yes
0: Not
detected
1: Detected
2: Unknown
0: 20 s
1: 30 s
1: Start
1: Start
1: Start
1: Start
1: Start
1: Start
SM