Ricoh A230 Service Manual page 930

Hide thumbs Also See for A230:
Table of Contents

Advertisement

TROUBLESHOOTING
3 Change the "ISA MEM BLOCK BASE" setting as follows:
• ISA MEM BLOCK BASE: No/ICU → D000
• ISA MEM BLOCK SIZE: 8k
4 Press "Esc" to exit "PNP AND PCI SETUP".
5 Choose "SAVE & EXIT SETUP".
Conflict with a plug and play ISA device
1. Shut down the computer.
2. Remove the ISA device that is in conflict with the SwapBox.
3. Restart the computer and see if the SwapBox and the SwapFTL work under the
Windows environment.
Conflict with a legacy ISA device
Either remove the ISA device that is in conflict with the SwapBox to change its
jumper settings, or run the setup utility of the device to change the setting.
4.2 "FAILED TO OPEN PCCARD" ERRORS
4.2.1 TIMELAG TO LOADING DRIVER
Windows requires a certain time, which depends on system performance, to enable
card services for a flash memory card after inserting it in a PC card socket.
If you try to read, erase, or write to the card before the card service is ready, you
receive a "Failed to open PCCard" error.
Wait for about 30 s, then try again.
4.2.2 PCCARD NOT CONFIGURED
If the PCCard icon in the Windows Control Panel is not configured, you receive a
"Failed to open PCCard" error when you try to access the card.
Configure the PCCard icon using Control Panel as explained in the driver
installation procedure.
4.2.3 RESOURCE CONFLICT
If you receive a "Failed to open PCCard" error even if the SwapBox looks correctly
configured in the device manager, a memory address conflict is causing the error.
Refer to section 4.1.2 to solve the problem.
SM
18-8
A203/A231/A232