Ricoh A230 Service Manual page 1083

Hide thumbs Also See for A230:
Table of Contents

Advertisement

Rev. 01/2000
SC542: Fusing temperature warming-up error
-Definition- [A]
The fusing temperature does not reach the fusing standby temperature within 135
sec (35CPM machines) or 145 seconds (45CPM machines) after the main power
switch is turned on.
- Possible causes -
• Fusing thermistor defective or out of position
• Fusing lamp open
• Fusing thermofuse open
• BICU defective
• Power supply board defective
• Poor fusing unit connection
SC543: Fusing overheat error 1
-Definition- [A]
A fusing temperature of over 231°C is detected for 5 seconds by the fusing
thermistor.
- Possible causes -
• Fusing thermistor defective
• BICU defective
• I/O board (IOB) defective
SC545: Fusing overheat error 2
-Definition- [A]
The fusing lamp stays on at full power for 30 seconds while in the stand-by
condition after warming-up is completed.
- Possible causes -
• Fusing thermistor out of position
SC546: Fusing ready temperature malfunction
-Definition- [A]
The fusing temperature goes 20 °C below or 20 °C over the stand-by
temperature after warm-up is completed.
- Possible causes -
• Poor thermistor connector connection
• Poor fusing unit connection