Tech Service Bulletin No. A230/A231/A232 – 032
Page 7 of 9
4. Connect the Extension Harness to the
connector that was detached from the Push
Switch in step 3. Fix the harness in place
with clamps (2 places).
5. Remove the Toner Bottle Unit. Attach 1 clamp
each to the bottom face of the Upper Cover
located just above the Toner Bottle insertion area
(middle right photograph) and to the Upper Cover
of the surface located to the left of the Fusing
Unit (lower right photograph). Clean the areas
where the clamps are to be attached with
alcohol.
Extension Harness
Toner Bottle
Unit Insertion
Wire Clamp
Fusing Unit
Continued...