Edge-Core ECS4110-28T Management Manual page 117

28/52-port gigabit ethernet layer 2+ switch
Hide thumbs Also See for ECS4110-28T:
Table of Contents

Advertisement

Table 6: Switch Main Menu (Continued)
Menu
Show
Configure Details
Configure Operation
CFM
Configure Global
Configure Interface
Configure MD
Add
Configure Details
Show
Configure MA
Add
Configure Details
Show
Configure MEP
Add
Show
Configure Remote MEP
Add
Show
Transmit Link Trace
Transmit Loopback
Transmit Delay Measure
Show Information
Show Local MEP
Show Local MEP Details
Show Local MIP
Show Remote MEP
Description
Shows list of configured ERPS rings, status, and settings
Configures ring parameters
Blocks a ring port using Forced Switch or Manual Switch commands
Connectivity Fault Management
Configures global settings, including administrative status, cross-
check start delay, link trace, and SNMP traps
Configures administrative status on an interface
Configure Maintenance Domains
Defines a portion of the network for which connectivity faults can
be managed, identified by an MD index, maintenance level, and
the MIP creation method
Configures the archive hold time and fault notification settings
Shows list of configured maintenance domains
Configure Maintenance Associations
Defines a unique CFM service instance, identified by its parent MD,
the MA index, the VLAN assigned to the MA, and the MIP creation
method
Configures detailed settings, including continuity check status and
interval level, cross-check status, and alarm indication signal
parameters
Shows list of configured maintenance associations
Configures Maintenance End Points
Configures MEPs at the domain boundary to provide management
access for each maintenance association
Shows list of configured maintenance end points
Configures Remote Maintenance End Points
Configures a static list of remote MEPs for comparison against
the MEPs learned through continuity check messages
Shows list of configured remote maintenance end points
Sends link trace messages to isolate connectivity faults by
tracing the path through a network to the designated target node
Sends loopback messages to isolate connectivity faults by
requesting a target node to echo the message back to the source
Sends periodic delay-measure requests to a specified MEP within a
maintenance association
Shows the MEPs configured on this device
Displays detailed CFM information about a specified local MEP in
the continuity check database
Shows the MIPs on this device discovered by the CFM protocol
Shows MEPs located on other devices which have been discovered
through continuity check messages, or statically configured in the
MEP database
– 117 –
| Using the Web Interface
C
3
HAPTER
Navigating the Web Browser Interface
Page
500
500
516
520
523
527
527
527
527
527
532
532
532
532
537
537
537
538
538
538
540
542
544
546
547
548
549

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecs4110-28pEcs4110-52tEcs4110-52p

Table of Contents