Multiturn Limit Disagreement Alarm (A.cc0) - YASKAWA SGDV series User Manual

Ac servo drives e-v series
Table of Contents

Advertisement

Set the value, the desired rotational amount -1, to Pn205.
Factory Setting (= 65535)
Rotational
0
data

4.5.7 Multiturn Limit Disagreement Alarm (A.CC0)

When the multiturn limit set value is changed with parameter Pn205, a multiturn limit disagreement alarm
(A.CC0) will be displayed because the value differs from that of the encoder.
Alarm
Display
A.CC0
Multiturn Limit Disagreement
If this alarm is displayed, perform the operation described below and change the multiturn limit value in the
encoder to the value set in Pn205.
Step
Display after Operation
A . C C 0
F n 0 1 2 : S o f t V e r
1
F n 0 1 3 : M t u r n L m S e t
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
A . C C 0
M u l t i t u r n L i m i t
2
S t a r t
R e t u r n : [ S E T ]
A . C C 0
M u l t i t u r n L i m i t
3
S t a r t
R e t u r n : [ S E T ]
A . C C 0
F n 0 1 2 : S o f t V e r
4
F n 0 1 3 : M t u r n L m S e t
F n 0 1 4 : O p t I n i t
F n 0 1 B : V i b l v l I n i t
5
To enable the change in the setting, turn the power OFF and ON again.
+32767
Forward
Reverse
-32768
Motor rotations
Alarm Name
Alarm Output
- F U N C T I O N -
S e t
: [ D A T A ]
S e t
: [ D A T A ]
- F U N C T I O N -
Other Setting (≠65535)
Pn205 setting value
Rotational
0
data
Different multiturn limits have been set in the
OFF (H)
encoder and SERVOPACK.
Keys
Press the
Key to select the utility function. And
press the
or
Press the
Key to view the execution display of
Fn013.
Note: If the display is not switched and "NO-OP" is
displayed in the status display, the Write Pro-
hibited Setting (Fn010 = 0001) is set. Check
the setting and reset.
Press the
Key to set the multiturn limit value.
When the setting is completed, the status display
shows "DONE" for one second. The status display
then returns to show "A.CC0" again.
Note: If the
Key, the multiturn limit value will not be reset.
Press the
Key to return to the display the proce-
dure 1.
4.5 Absolute Encoders
Reverse
Forward
Motor rotations
Meaning
Operation
Key to select the Fn013.
Key is pressed instead of the
4
4-47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgdv-coaSgmvv

Table of Contents