323005
power supply configuraTion
Possible configuration way for
power supply
Mode 1
Resistor configuration
√
Keyboard configuration √
RS232 configuration
√
meaning of each
configuraTor socKeT pin
NNN: Power supply address (range
1–256), only when TYP= 1, the power
supply address will be valid. It means
when TYP= 0, there is no need to
configure NNN.
FF Min: the floor number where this
power management starts from.
FF Max: the floor number where this
power management ends. FF Max
must over or equal to FF Min.
#II: number of apartments on each
floor (at Mode 1, the default number
is 4, no need to set).
#Min handset: the address of the
first address managed by this
Configurators position for power supply
WWW.LEGRAND.COM
configuration
N
N
N
Mode 2
CF4
√
CF5
√
CF6
√
CF7
CF8
CF9
CF10
CF11
Type
ASR
M
LE
power supply).
#Max handset: the last handset
address managed by this
Power supply).
TYP: configuration position for the
power supply function. Used to
enable or disable the power supply
management function and the smart
power function.
ASR: set how much current the
Mode 1 (1 pwS for each floor) Mode 2
NNN
NNN
FF Min
FF Min
#II
FF Max
FF Max
Type
Type
ASR
ASR
M
M
LE
LE
power supply will offer to each
handset for the alarm function.
M: position to choose configuration
Mode. connecting configurator 0
means choosing Mode 1 or Mode 2.
LE: configuration position for smart
power supply management. Only
valid when TYP=1. When TYP= 0, no
need to configure that position.
N
N
N
CF4 CF5 CF6 CF7
FF
FF
N
N
N
min
min
CF8 CF9 CF10CF11 TYP ASR M
FF
FF
TYP ASR M
max
max
D45 SyStEm
#I
#I
LE
LE
GUIDE
49