Table 6: case 9 to case 12, the quantity of devices managed by 323005 (Power supply).
How many apartments
on every floor
Total Qty of
handsets
2 apartments/floor
(Don't use extra power cable)
2 apartments/floor
(use extra power cable)
4 apartments/floor
8 apartments/floor
12 apartments/floor
16 apartments/floor
20 apartments/floor
24 apartments/floor
28 apartments/floor
32 apartments/floor
36 apartment/floor
*1: 2 small EP and 1 EP can work at the
same time with handsets connected
to the same power supply.
*2: 1 small EP and 1 EP can work at the
same time with handsets connected
to the same power supply.
*3: 3 small EP and 1 EP can work at the
same time with handsets connected
to the same power supply.
Remark: In table 4, table 5 and table 6 , in case 4, case 5, case 6, case 10, case 11 and case 12, the quantity of handsets is only for 323005.
If using 323010, Please refer to table 7;
WWW.LEGRAND.COM
Case 9
Total Qty of
Floor limit
handsets
16
max: 8 floors
16 [*2]
16
max: 8 floors
36 [*3]
16
max: 4 floors
24 [*3]
16
max: 2 floors
32 [*3]
16
max: 2 floors
36 [*3]
16
max: 1 floor
36 [*3]
16
max: 1 floor
36 [*3]
16
max: 1 floor
36 [*3]
16
max: 1 floor
36 [*3]
16
max: 1 floor
36 [*3]
16
max: 1 floor
36 [*3]
The information of table 4 to table 6
is based on the below conditions:
A) 50 m cable from Floor shunt
to handset.
B) 5 m cable between floors.
C) 0.5 m cable between Floor shunt
and Floor shunt in same floor for
the projects with more than one
floor shunt on each floor.
handSet
Case 10
Case 11
Total Qty of
Floor limit
handsets
max: 16 floors
4 [*3]
max: 6 floors
4 [*3]
max: 4 floors
4 [*3]
max: 3 floors
4 [*3]
max: 3 floors
4 [*3]
max: 2 floors
4 [*3]
max: 2 floors
4 [*3]
max: 2 floors
4 [*3]
max: 2 floors
4 [*3]
max: 2 floors
4 [*3]
max: 1 floor
4 [*3]
D) Between Power supply and 1st
E) The data in above table also
Case 12
Total Qty of
Floor limit
Floor limit
handsets
max: 1 floor
12 [*1]
max: 6 floors
max: 1 floor
12 [*1]
max: 6 floors
max: 1 floor
12 [*1]
max: 3 floors
max: 1 floor
12 [*1]
max: 2 floors
max: 1 floor
12 [*1]
max: 1 floor
max: 1 floor
12 [*1]
max: 1 floor
max: 1 floor
12 [*1]
max: 1 floor
max: 1 floor
12 [*1]
max: 1 floor
max: 1 floor
12 [*1]
max: 1 floor
max: 1 floor
12 [*1]
max: 1 floor
max: 1 floor
12 [*1]
max:1 floor
Floor shunt, for the connection
use 2 wire cables.
limited by distance. Example: 4
apartment on every floor. Case 1.
can have 40 handsetsand the Max.
per floor is 10. In other words, the
distance must less than 45 m,
45 m= [(40/4)-1]*5.