The flexible configuration can be
used in installation of up to 4000
apartments, with the maximum
limits listed in the linked table (that
can be shared with the people in
charge of the configuration – and can
be completed using how much row
we want to communicate).
The simplified configuration can be
applied to a simplified installation
or to a district of the complete
installation, inheriting the limits of
the chosen configuration type.
defaulT Behaviour of
aparTmenT funcTions
The default functions are available
both with simplified and flexible
system configuration.
physical configuraTion
(insTallaTion)
The devices may be configured in
three ways:
Use of physical configurators: this
means placing the right numbered
configurators in the devices in the
right position (depending on the
design of the configuration);
define a procedure of
configuration of each device that
uses its resources (keypad, LCD,
configuraTion mode for
The whole sysTem
Two configuration modes available,
configuration Mode 1 and
configuration Mode 2. The main
characteristics for each configuration
Mode are described below:
WWW.LEGRAND.COM
nuMBerS
nuMBerS of floorS
of riSer ShuntS
# ff
99
10
20
50
11
90
66
10
13
50
7
90
50
10
10
50
5
90
25
10
5
50
12
10
6
20
The default functions are:
Self-powering of the main riser EP;
repeated pression on self power on
function changes on next address
riser EP;
LEDs, etc. ) in order assign to the
device the designated number;
use the PC on the field to
total nuMBer of apartMentS in the
inStallation:
Number of apt. for each "district"
(AS02: LAN-8Wire interface)
Total number of units/riser for each district
Total number of apt./villas for each riser:
Total number of apt./villas for each riser:
Total number of apt./villas for each riser:
Total number of apt./villas for each riser:
*1*: Below are the rules for system configuration (Mode 1).
#ff
#ii
for each riSer
for each floor
≤ 20
≤4
> 20
≤ 4
≤20
> 4
> 20
> 4
nuMBerS of flatS/floor
#ii
4
4
4
6
6
6
8
8
8
16
16
32
32
call to Switchboard is to main
Switchboard;
alarm collected by main
Switchboard.
download the results of the design
configuration done on a PC, on to
each device using its MAC address.
Virtually no liMitS
4.000 apt. or villas.
400
800 (if only 1 handset in each apt.)
400 (if only 2 handsets in each apt.)
265 (if only 3 handsets in each apt.)
800 (up to 5 handsets in each apt. with D45 apt. interface)
can SySteM configuration Mode 1 Be uSed?
YES, but it is necessary to calculate the total number of handsets for
whole system according to Mode 1 configuration. If the total number
calculated is 4000 or less, Mode 1 configuration is possible, if the total
number is over 4000, Mode 2 must be considered.
NO
NO
NO
D45 SyStEm
nuMBer of apart. in
each unit/riSer
40
200
360
60
300
540
80
400
720
160
800
320
640
GUIDE