Assigning Sensor Names; Programming The Fax/Ddi Module - Siemens Hicom 100 E Service Manual

Table of Contents

Advertisement

Programming guide
Programming expansion modules
10.8.2.8

Assigning sensor names

A name which will appear in the optiset display of the destination extension called can be
assigned for each sensor. An optiset (E) memory telephone is necessary for this purpose.
Example: sensor 1 is to be called "Water".
Input sequence
A
2 6 8
*
B
C
Water
D
<OK>
E
<F8>
A sensor name can be deleted with the F3 key under point C.
10.8.3

Programming the fax/DDI module

A connected fax/DDI module which is recognised by the system (see Chap. 5 "Installation" in
the Service Manual) can be programmed to perform the following functions:
1.
Fax option: fax recognition function for analogue trunk lines and the autofax function
2.
DDI option: pseudo-DTMF DDI for analogue trunk lines
3.
Fax/DDI option: combination of fax recognition and pseudo-DTMF DDI
4.
Announcement without notification: announcement without notification feature
(as of SW 2.0.2)
5.
Autofax: additional fax signals from lines that are not assigned to a fax option.
Up to 4 fax/DDI modules can be connected to the system.
The following programming procedures should be performed step by step.
.
The first step entails defining the planned option type as well as the number of
modules.
10-82
Meaning
Sensor names
(select sensor 1–4 with "+" and "–" or
directly with "#")
Change input
Enter name
Confirm input
Return to Start menu
Display
Sensor no.1: –
Sensor no.1:
Sensor no. 1: Water
Sensor no. 1: Water
System administration
A31003-K16-X001-3-7620
Hicom 100 E Version 2.1, Service manual
,
07/99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hicom 118Hicom 108Hicom 118-2Hicom 112

Table of Contents