Controlling The Door Opener Via A Door Opener Adapter; Diverting Calls To Receiving Extension For The Doorbell - Siemens Hicom 100 E Service Manual

Table of Contents

Advertisement

Programming guide
Station attributes
10.5.3.3
Controlling the door opener via a door opener adapter (as of SW version
2.0.2)
An existing power source can be connected to an electromagnetic door opener via a floating
contact on a door opener adapter. A door opener can be set up for each door (1 to 4). "DTMF"
must be released for the door opener in question if it is also to be operated by entering a code
at the entrance telephone.
Example: a door opener with DTMF is set up for door 2.
Input sequence
A
2 3 3
B
+
C
*
D
2
E
<OK>
F
<F8>
A door opener feature without DTMF can be activated by entering "1" under point D. An
activated door opener feature can be deactivated by entering "0" under point D.
10.5.3.4
Diverting calls to receiving extension for the doorbell (as of SW version
2.0.2)
Even if an external diversion destination has been programmed for the receiving extension of
a doorbell, incoming calls at this extension are not automatically diverted to the external
destination. Diversion of calls from the entrance telephone to an external destination can be
released for each door (1–4).
Example: calls from door 2 should also be diverted to external destinations set for the receiving
extension for the doorbell.
Input sequence
A
2 3 4
B
+
C
*
D
1
E
<OK>
<F8>
F
Doorbell diversion can be blocked again by entering "0" under point D.
10-28
Meaning
Door opener for door 1
(select door 1 to 4 with "+" and "–" or
directly with "#")
Scroll to door 2
Change input
Door opener feature with DTMF ON
Confirm input
Return to Start menu
Meaning
Doorbell diversion for door 1
(select door 1 to 4 with "+" and "–" or
directly with "#")
Scroll to door 2
Change input
Doorbell diversion ON
Confirm input
Return to Start menu
Display
Door 1: not available
Door 2: not available
Door 2:
Door 2: with DTMF
Door 2: with DTMF
System administration
Display
Door 1: do not activate
Door 2: do not activate
Door 2:
Door 2: activate
Door 2: activate
System administration
A31003-K16-X001-3-7620
Hicom 100 E Version 2.1, Service manual
,
07/99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hicom 118Hicom 108Hicom 118-2Hicom 112

Table of Contents