Trunk Access; Classes Of Service Up To Sw Version 2.0.1; Classes Of Service As Of Sw Version 2.0.2; Allowed Numbers List Up To Sw Version 2.0.1 - Siemens Hicom 100 E Service Manual

Table of Contents

Advertisement

Programming guide
Station attributes
10.5.4

Trunk access

10.5.4.1

Classes of service up to SW version 2.0.1+

In Hicom 100E (up to SW 2.0.1+), 5 levels of trunk access are available for each extension.
These five levels are:
<0> No trunk access. *
<1> Outward restricted (+ central abb. dialling dests.). *
<2> Access restricted to the numbers in the allowed numbers list. *
<3> Access restricted for the numbers in the barred numbers list. *
<4> Trunk access, no restrictions.
*)
Central abbreviated dialling destinations can be dialled without restriction.
10.5.4.2

Classes of service as of SW version 2.0.2

In Hicom 100E (up to SW 2.0.2), 15 levels of trunk access are available for each extension.
These 15 levels are:
<0> No trunk access. *)
<1> Outward restricted. *)
<2-7> Access restricted to the numbers in one of the allowed numbers lists (1 to 6). *)
<8-13> Access restricted for the numbers in one of the barred numbers lists (1 to 6). *)
<14> Trunk access, no restrictions.
*) Central abbreviated dialling destinations can be dialled without restriction.
10.5.4.3

Allowed numbers list up to SW version 2.0.1+

The numbers in this list can be dialled by an extension with class-of-service level <2>. Suffix
dialling of additional numbers is not restricted.
45 items are available for allowed numbers.