Other module type detected > module will not be put into operation.
Same module type detected, but smaller number of channels > module will be put into
operation with fewer ports; there will be a gap.
Same module type detected, but larger number of channels > module will be put into
operation with the number of channels stored in the EEPROM , the additional ports will
not be activated.
New module in empty slot:
The module will be plugged last in accordance with the equipping sequence > all
modules will be put into operation, the numbering plan will be updated with no
gaps.
If the module is plugged in front of a corresponding module in accordance with the
equipping sequence, it will be put into operation and appended to the last module
in the extension number plan.
Re-initialising > The system will be returned to its pre-initialisation status with redefined
passwords. The data contained in the EEPROM regarding the system configuration will be
erased, and the configuration status can be modified as required.
If expansion work requiring re-initialisation of the extension number plan is carried out, pro-
ceed as follows:
Enter the re-initialisation password before making the change > the existing
configuration will be erased.
Disconnect the system, release and remove the PSU/UPS, plug in new module(s).
Insert and screw the PSU/UPS, connect system, the extension number plan will be set
up with no gaps as in the case of initial activation.
Caution
!
Extension-related data will be changed if the extension number plan for users is
changed.
If users are connected on the STLS module (S
be based on the MSNs of the terminals irrespective of the equipping scheme. The following
scheme applies to the allocation of the default MSNs of the 16 possible S
no MSN is assigned to the terminal):
S0 port
1
2
:
:
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
Default MSN
74
73
...
...
Extension and line number allocation
bus), the standard extension number will
0
Installation
ports (used if
0