Overview of modules
Function expansions with options bus
Contact
1
R1 from trunk 1a
2
T1 from trunk 1b
3
R2 from trunk 2a
4
T2 from trunk 2b
5
R3 from trunk 3a
6
T3 from trunk 3b
7
R4 from trunk 4a
8
T4 from trunk 4b
9
10
11
12
13
14
15
16
* = or to the free analogue port
Table 3-23
Contact assignment of the ALUM module
TRUNK
ALUM
R1
Relay
K1-B
K1-C
Relay
AE1
Normal telephone
Figure 3-17
Basic layout of the ALUM module
3-28
Port X3
Port X3
T1
K2-B
BT1
AT1
Port X6
TA1
TB1
K2-C
BE1
Port X4
Port X4
AE1 to ext. 1a
BE1 to ext. 1b
AE2 to ext. 2a
BE2 to ext. 2b
AE3 to ext. 3a
BE3 to ext. 3b
AE4 to ext. 4a
BE4 to ext. 4b
Trunk module
HICOM 100 E
Subscr. module
Hicom 100 E Version 2.1, Service manual
Port X6
AT1 to TLA a
BT1 to TLA b
AT2 to TLA a
BT2 to TLA b
AT3 to TLA a
BT3 to TLA b
AT4 to TLA a
BT4 to TLA b
TA1 to SLA* a
TB1 to SLA* b
TA2 to SLA* a
TB2 to SLA* b
TA3 to SLA* a
TB3 to SLA* b
TA4 to SLA* a
TB4 to SLA* b