Programming guide
Station attributes
10.5.4.9
Reference extensions
Classes of service are assigned on a line-specific basis for a reference extension, Section
10.5.4.
Example: during the day, ext. 11 has "unrestricted trunk access" and is the reference extension
for all other extensions with "unrestricted trunk access" during the day. Ext. 13 is authorised to
telephone in accordance with the allowed numbers list (as of SW 2.0.2 = list 1) and is the
reference extension for all other extensions restricted to the numbers in the allowed numbers
list (as of SW 2.0.2 = list 2). Two lines are connected.
Input sequence
A
1 4 1
B
#
C
13
D
<OK>
E
*
F
2
G
*
H
3
J
<OK>
+
K
L
*
M
3
N
<OK>
O
<F8>
Classes of service <0> to <4> or <0> to <14> can be assigned by entering a value from "0"–
"4" or "0"–"14" under points H or M.
10-34
Meaning
Trunk access during the day for ext. 11
on line 1
(select ext. 11–74 directly with "#", and
lines 1–32 by scrolling with "+" and "–
")
Select extension
Enter ext. 13
Trunk access during the day for ext. 13 Ext. 13: as for ext. 11
Change input
Enter new data
Change input
Up to 2.0.1+ authorized in accordance
with allowed numbers list as of 2.0.2
authorized in acc. with allowed
numbers list 1
Confirm input
Scroll to line 2
Change input
Up to 2.0.1+ authorised in acc. with
allowed numbers list as of 2.0.2
authorised in acc. with allowed
numbers list 1
Confirm input
Return to Start menu
Display
Ext. 11, line 1: seized
Ext.:
Ext.: 13
Change for ext. 13:
Ext. 13, line 1: seized
Ext. 13, line 1:
Ext.: 13, line 1: allowed
numbers list or
allowed nos. list 1
Ext. 13, line 1: allowed
numbers list or
allowed nos. list 1
Ext. 13, line 2: seized
Ext. 13, line 2:
Ext. 13, line 2: allowed
numbers list or
allowed nos. list 1
Ext. 13, line 2: allowed
numbers list or
allowed nos. list 1
System administration
A31003-K16-X001-3-7620
Hicom 100 E Version 2.1, Service manual
,
07/99