Analogue Trunk; Setting Analogue Signalling Method - Siemens Hicom 100 E Service Manual

Table of Contents

Advertisement

Programming guide

Analogue trunk

Example: a multi-device connection is to be connected to ISDN port 1 of an STLS 2 or 4
module .
Input sequence
A
1 9 3
B
*
C
6
D
<OK>
E
<F8>
If necessary, the ISDN port is reset to "default" ("automatic" as of SW version 2.0.2) by
entering "0" under point C.
10.2
Analogue trunk
A TLA 2 or TLA 4 module is the minimum requirement to connect analogue trunk lines (for 2 or
4 lines).
10.2.1

Setting analogue signalling method

The system is equipped by default with a mechanism for automatically recognising the
signalling method when connecting the system to analogue trunk lines. The signalling method
can also be permanently configured for each route.
Example: defining the signalling method for line 1 to DTMF or DP.
Input sequence
A
201
B
*
C
1 or
2
D
<OK>
E
<F8>
Automatic recognition of the signalling method can be set by entering "0" under point C.
10-4
Meaning
Port configuration of port 1
(select port 1–16 with "+" and "–" or
directly with "#")
Change input
PMP Euro-ISDN trunk
Confirm input
Return to Start menu
Meaning
Signalling method line 1
(select line 1–32 with "+" and "–" or
directly with "#")
Change input
1 for DTMF or
2 for DP
Confirm input
Return to Start menu
Display
Port 1: default
Port 1
Port 1: PMP Euro exch.
Port 1: PMP Euro exch.
System administration
Display
Line 1: automatic
Line 1
Line 1: DTMF or
Line 1: DP
Line 1: DTMF or
Line 1: DP
System administration
A31003-K16-X001-3-7620
Hicom 100 E Version 2.1, Service manual
,
07/99